Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Application: | Communication |
| Type: | Single-mode Fiber |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Fishing-line Optical Cable(GJJA)
Optical cables for vertical wiring in buildings, which is a major component of the dropsegment in FTTx networks, refer to the drop cables going from ducts in buildings intorooms. Vertical wiring is mainly applied to high-storey buildings, super high-storeybuildings, buildings with high-density subscribers and large information processing centers such as data centers.
• Using G657B3 optical fibres, with excellent anti-bending performance
• Small size, precisely controlled route
• Transparent, suitable for indoor application
• Compatiable with G.652D and G.657A2 optical fibres
• Hard & resilient buffer material ensures easy installation
• Indoor wiring



| Type | Cable diameter | Cable weight | Tensile strength | Bending radius | Crush | Storage |
| (mm) | (Kg/km) | Long/short term | Dynamic/static | Long/short term | temperature | |
| (N) | (mm) | (N/100mm) | (ºC) | |||
| GJJA | 0.9 | 0.7 | 3/6 | 60/30 | 100/500 | -40 to +70 |
| Specifications(G657B3) | ||||
| Characteristics | Conditions | Specified values | Units | |
| Optical Characteristics | ||||
| Attenuation | 1310nm | ≤0.35 | [dB/km] | |
| 1383nm(after H2-aging) | ≤0.35 | [dB/km] | ||
| 1550nm | ≤0.21 | [dB/km] | ||
| 1625nm | ≤0.23 | [dB/km] | ||
| Attenuation vs. Wavelength | 1285-1330nm, in reference to 1310nm | ≤0.03 | [dB/km] | |
| Max. α difference | 1525-1575nm, in reference to 1550nm | ≤0.02 | [dB/km] | |
| Zero Dispersion Wavelength(λ0) | -- | 1300-1324 | [nm] | |
| Zero Dispersion Slope(S0) | -- | ≤0.092 | [ps/(nm2·km)] | |
| PMD | Maximum Individual Fibre | -- | ≤0.1 | [ps/√km] |
| Link Design Value(M=20,Q=0.01%) | -- | ≤0.06 | [ps/√km] | |
| Typical Value | -- | 0.04 | [ps/√km] | |
| Cable Cutoff Wavelength (λCC) | -- | ≤1260 | [nm] | |
| Mode Field Diameter(MFD) | 1310nm | 8.2-9.0 | [μm] | |
| 1550nm | 9.1-10.1 | [μm] | ||
| Effective Group Index of Refraction(Neff ) | 1310nm | 1.468 | -- | |
| 1550nm | 1.469 | -- | ||
| Point Discontinuities | 1310nm | ≤0.05 | [dB] | |
| 1550nm | ≤0.05 | [dB] | ||
| Geometrical Characteristics | ||||
| Cladding Diameter | -- | 125.0±0.7 | [μm] | |
| Cladding Non-Circularity | -- | ≤0.7 | [%] | |
| Coating Diameter | -- | 235-245 | [μm] | |
| Coating-Cladding Concentricity Error | -- | ≤12.0 | [μm] | |
| Coating Non-Circularity | -- | ≤6.0 | [%] | |
| Core-Cladding Concentricity Error | -- | ≤0.5 | [μm] | |
| Curl(radius) | -- | ≥4 | [m] | |
| Delivery Length | -- | Up to 25.2 | [km/reel] | |
| Environmental Characteristics | 1310nm, 1550nm & 1625nm | |||
| Temperature Dependence Induced Attenuation | -60ºC to +85ºC | ≤0.05 | [dB/km] | |
| Temperature-Humidity Cycling Induced Attenuation | -10°C to +85°C, 98% RH | ≤0.05 | [dB/km] | |
| Watersoak Dependence Induced Attenuation | 23°C,for 30 days | ≤0.05 | [dB/km] | |
| Damp Heat Dependence Induced Attenuation | 85°C and 85% RH,for 30 days | ≤0.05 | [dB/km] | |
| Dry Heat Aging | 85ºC,for 30 days | ≤0.05 | [dB/km] | |
| Mechanical Specification | ||||
| Proof Test | -- | ≥9.0 | [N] | |
| -- | ≥1.0 | [%] | ||
| -- | ≥100 | [kpsi] | ||
| Macro-bend Induced Loss | 1 Turn Around a Mandrel of 10 mm Radius | 1550nm | ≤0.03 | [dB] |
| 1 Turn Around a Mandrel of 10 mm Radius | 1625nm | ≤0.1 | [dB] | |
| 1 Turn Around a Mandrel of 7.5 mm Radius | 1550nm | ≤0.08 | [dB] | |
| 1 Turn Around a Mandrel of 7.5 mm Radius | 1625nm | ≤0.25 | [dB] | |
| 1 Turns Around a Mandrel of 5 mm Radius | 1550nm | ≤0.15 | [dB] | |
| 1 Turns Around a Mandrel of 5 mm Radius | 1625nm | ≤0.45 | [dB] | |
| Coating Strip Force | typical average force | 1.5 | [N] | |
| peak force | 1.3-8.9 | [N] | ||
| Dynamic Fatigue Parameter(nd) | -- | ≥20 | -- | |